名    称: 超滤离心管Amicon Ultra-0.5 Centrifugal Filter Unit 3K
英文名称: Amicon Ultra-0.5 Centrifugal Filter Unit with Ultracel-3 membrane, Qty/PK: 96
原始链接: 点击查看
品    牌: Millipore
规    格: 96 PK
货    号: UFC500396
CAS   号: 暂无CAS号
保存环境: 数据暂无
区    域:
厂家报价: ¥3377.00元
  • 经销商信息
  • 详细描述
  • 品牌信息
  • 相关文档
暂无经销商!
  • 详细描述

 

  • Concentrates 500 µL down to 15 µL
  • Concentration factor 25 x to 30 x
  • High sample recovery (greater than 90% of dilute starting solution)
  • Fast processing time - 10 to 30 minutes
  • Consistent recoveries thanks to the reverse spin capability
  • Reverse spin capability provides consistent recoveries

 

 

 

Applications

 

  • Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
  • Purification of macromolecular components found in tissue culture extracts or cell lysates
  • Primer removal, PCR cleanup, removal of linkers or macromolecular labels from a reaction mix, and protein removal prior to HPLC
  • Desalting, buffer exchange and protein dialysis
  • Size exclusion and protein fractionation

 

Not sure if you found the right Amicon for your application?
» Search with our new Amicon Ultra Selector tool.

Material Supplied

The Amicon Ultra-0.5 device is supplied with two microcentrifuge tubes. During operation, one tube is used to collect filtrate; the other tube is to recover the concentrated sample.

Performance – Protein Concentration

 

Spin 
Conditions: 40º fixed angle rotor, 14,000 x g, room temperature, 
500 µL starting volume. Protein markers used: Cytochrome c for 3K and 
10K, BSA for 30K and 50K, and IgG for 100K, n=8.

Spin Conditions: 40º fixed angle rotor, 14,000 x g, room temperature, 500 µL starting volume. Protein markers used: Cytochrome c for 3K and 10K, BSA for 30K and 50K, and IgG for 100K, n=8.

Typical Concentrate Volume/Concentration Factor vs. Spin Time

Concentrate Volume / Concentration Factor
  3K device 10K device 30K device 50K device 100K device
Spin time (min) Conc. Volume (µL) Conc. Factor (x) Conc. Volume (µL) Conc. Factor (x) Conc. Volume (µL) Conc. Factor (x) Conc. Volume (µL) Conc. Factor (x) Conc. Volume (µL) Conc. Factor (x)
5 215 2 66 7 42 12 28 18 58 9
10 114 4 35 14 23 22 20 25 19 26
15 80 6 22 22 19 27 17 30 15 33
20 62 8 20 24 17 30 15 33 13 36
30 48 10 15 31 15 32 15 36 11 41
Spin Conditions: 40º fixed angle rotor, 14,000 x g, room temperature, 500 µL starting volume. Protein markers used: Cytochrome c for 3K and 10K, BSA for 30K and 50K, and IgG for 100K, n=12. Shaded volumes were used for the calculation of protein recovery in the Typical Concentrate Recovery table.

Typical Retention of Protein Markers

Marker/Concentration Molecular Weight Device NMWL % Retention Spin Time (min)
α-Chymotrypsinogen (1 mg/mL) 25,000 3K > 95 30
Cytochrome c (0.25 mg/mL) 12,400 > 95 30
Vitamin B-12 (0.2 mg/mL) 1,350 < 42 30
α-Chymotrypsinogen (1 mg/mL) 25,000 10K > 95 15
Cytochrome c (0.25 mg/mL) 12,400 > 95 15
Vitamin B-12 (0.2 mg/mL) 1,350 < 42 15
BSA (1 mg/mL) 67,000 30K > 95 10
Ovalbumin (1 mg/mL) 45,000 > 95 10
Cytrochorme c (0.25 mg/mL) 12,400 < 35 10
BSA (1 mg/mL) 67,000 50K > 95 10
Ovalbumin (1 mg/mL) 45,000 ~ 40 10
Cytrochorme c (0.25 mg/mL) 12,400 < 20 10
Thyroglobulin (0.5 mg/mL) 677,000 100K > 95 10
IgG (1 mg/mL) 156,000 > 95 10
Ovalbumin (1 mg/mL) 45,000 < 30 10
Spin Conditions: 40º fixed angle rotor, 14,000 x g, room temperature, 500 µL starting volume, n=12.

Typical Concentrate Recovery

Marker/Concentration Molecular Weight Device NMWL Spin Time (min) Concentrate Volume (µL) Concentration Factor (x) Concentrate Recovery (%)
Cytochrome c (0.25 mg/mL) 12,400 3K 30 48 10 98
Cytochrome c (0.25 mg/mL) 12,400 10K 15 22 22 93
BSA (1 mg/mL) 67,000 30K 10 23 22 97
BSA (1 mg/mL) 67,000 50K 10 20 25 92
IgG (1 mg/mL) 156,000 100K 10 19 26 92
Spin Conditions: 40º fixed angle rotor, 14,000 x g, room temperature, 500 µL starting volume, n=12. The shaded volumes were taken from the Typical Concentrate Volume/Concentration Factor vs. Spin Time table.

Desalting or Diafiltration

Desalting, buffer exchange or diafiltration are important methods for removing salts or solvents in solutions containing biomolecules. The removal of salts or the exchange of buffers can be accomplished in the Amicon Ultra-0.5 device by concentrating the sample, then reconstituting the concentrate to the original sample volume with any desired solvent. The process of "washing out" can be repeated until the concentration of the contaminating microsolute has been sufficiently reduced. See example below.

 

 

Description:
Amicon Ultra-0.5, Ultracel-3 Membrane, 3 kDa
 
Trade Name:
Amicon
Qty/Pk:
96
Key Applications:
  • Protein Extraction
  • Protein Purification
  • Sample Prep
 
Application Notes:
Fixed angle rotor: 14,000 x g for concentration spin; 1,000 x g for reverse spin
 
Length, cm (in):
4.99 (0.196)
 
Centrifugal Application:
Protein Concentration and Desalting
Chemistry:
Regenerated Cellulose
Color Code:
Clear
 
Minimum Final Concentrate Volume, µL:
15
Filter Type:
Ultrafiltration
Length, mm:
49.9
 
NMWL (KDa):
3
Diameter, mm:
10.8
 
Filter Code:
PL
 
Volume, mL:
0.5
 
Product Name:
Amicon Ultra-0.5 Centrifugal Filter Unit with Ultracel-3 membrane
 
Filtration Area, cm²:
1
 
Device Material:
  • Housing: Styrene/butadiene
  • Cap and Tube: Polypropylene 

 

  • 品牌信息
  • 相关文档